INNOVATIVE METHODOLOGY
1Department of Medicine, Vanderbilt University, Nashville, Tennessee; 2Department of Medicine, Case Western Reserve University, Cleveland, Ohio; 3Department of Molecular Physiology and Biophysics, Vanderbilt University; and 4The Mouse Metabolic Phenotyping Center, Vanderbilt University School of Medicine, Nashville, Tennessee
Submitted 10 March 2008 ; accepted in final form 21 July 2008
| ABSTRACT |
|---|
|
|
|---|
glycosylated hemoglobin; methodology; mice
Measurement of GlyHb provides a critical parameter for assessing long-term glycemic control and predicting the incidence of diabetic complications in diabetic patients (1, 1a). In humans, glycosylation of NH2-terminal valine of the hemoglobin β-chain is known as hemoglobin A1c (Hb A1c) and represents the major form of GlyHb (7). Several methods for determining GlyHb exist, including ion-exchange high-performance liquid chromatography (HPLC), boronate affinity HPLC (23), and an antibody-based approach (2). Ion- exchange HPLC determines GlyHb on the basis of altered Hb charge caused by linkage with glucose molecules, whereas the boronate affinity HPLC measures GlyHb by the presence of coplanar vicinal hydroxyl and/or carbonyl groups of hexoses (23). It has been demonstrated in humans that the boronate affinity HPLC approach determines total GlyHb with less interference from nonglycosylated hemoglobin compounds (23, 24).
Clinically, an immunochemistry-based approach that detects Hb A1c using a monoclonal antibody against human Hb A1c has been widely used (e.g., DCA 2000 analyzer) (2, 13). Advantages of this technique include the requirement for only a few microliters of blood, making it suitable for determining Hb A1c in mice and the rapid simplicity of measurement (18, 36). Although it has been demonstrated in humans that Hb A1c determined using DCA 2000 analyzer correlates with GlyHb measured using ion-exchange HPLC (2), a similar relationship in mice remains to be established. Validation of the relationship between Hb A1c, GlyHb, and glucose control in mice remains to be established but is critical for studies of diabetic complications in this species. Therefore, we undertook the present studies to characterize the relationship between fasting blood glucose and Hb A1c in mice.
| MATERIALS AND METHODS |
|---|
|
|
|---|
Generating diabetic mice.
Diabetes was induced using a low-dose streptozotocin protocol (40 mg·kg–1·day–1 for DBA/2J and 50 mg·kg–1·day–1 for C57BL/6J and KK/HlJ mice, made freshly in 0.1 mol/l citrate buffer, pH 4.0, ip injection daily for 5 consecutive days), as described previously (25). The induction of diabetes mellitus was defined as a blood glucose level measured using a B-Glucose Analyzer (HemoCue, Lake Forest, CA) >250 mg/dl in mice following a 6-h fast starting at 6:00 AM (25). More than 90% of mice developed hyperglycemia within 2 wk of the streptozotocin injection, and hyperglycemia persisted for the duration of the experimental period. All diabetic mice included in the present studies were diabetic for
8 wk.
Continuous monitoring of blood glucose in conscious mice. To definitely determine daily average blood glucose level in mice, we used the Continuous Glucose Monitoring System (CGMS; Meditronic MiniMed, Northridge, CA) to continuously measure blood glucose for 24 h. This system utilizes a subcutaneous glucose sensor such that interstitial fluid glucose reacts with the sensor's glucose oxidase layer, producing an electrical current that is proportional to glucose concentrations (21, 28). The electrical signal was collected every 10 s. These signals were averaged and saved to memory of the cable-tethered glucose monitor every 5 min. The data stored in the monitor were periodically downloaded into a computer for analysis. A correlation between interstitial glucose and blood glucose levels has previously been demonstrated in several species, including mice and humans (19, 27, 28). In the present studies, we adapted this system to mice.
A method for implantation of the subcutaneous glucose sensor in mice was established as described below. Briefly, a diabetic or control inbred mouse was restrained in a 50-ml centrifuge tube with air holes drilled in its tip. The fur on the lower back was shaved and the skin sterilized with an iodine pad, followed by washing with a 70% ethanol pad. The glucose sensor was inserted subcutaneously and fixed to skin using tissue glue (3M Vetbond Tissue Adhesive 1469SB). The mouse was then housed individually in a cage and allowed free access to water and food. The glucose signal was recorded by the glucose monitor placed outside the cage via a cable tethered to the mouse. Three to four measurements of blood glucose were performed during the daytime by puncturing saphenous vein as described previously (26), and the blood glucose values were input into the monitor to calibrate the glucose level. To minimize the effect of sensor implantation on blood glucose, the data recorded by the glucose sensor in the first 5 h were discarded.
Correlation between glucose levels in subcutaneous interstitium and blood. The validity of the CGMS has been established by studies in humans indicating that the interstitial glucose is proportional to blood glucose (27, 28). In the present studies, we examined the relationship between glucose levels in these two compartments in mice. To do this, we injected a 20% of glucose solution (1.5 g/kg body wt) intraperitoneally in mice implanted with the glucose sensor. Blood glucose concentration determined via a saphenous vein bleed and the electric current recorded using the glucose sensor were examined at several time points following glucose injection. A significant correlation between blood glucose level and the sensor current (n = 10, R2 = 0.762, P < 0.05) was observed, indicating the interstitial glucose sensitively reflects blood glucose in inbred mice.
Determination of Hb A1c.
Mouse immunoreactive Hb A1c was determined using DCA 2000 analyzer (Bayer, Elkhart, IN). This system automatically measures both Hb A1c and total hemoglobin in an
5-µl blood sample (2, 13). Total Hb is determined using potassium ferricyanide to oxidize Hb in the sample to methemoglobin. The methemoglobin then complexes with thiocyanate to form thiocyan-methemoglobin, and the colored species is measured. The extent of color development at 531 nm is proportional to the concentration of total hemoglobin in the sample. For the specific measurement of Hb A1c, the assay relies on inhibition of latex agglutination. An agglutinator causes agglutination of latex coated with an Hb A1c-specific monoclonal antibody. Increased agglutination causes increased light scattering, which is measured as an increase in absorbance at 531 nm. Hb A1c in whole blood specimens competes for the limited number of antibody-latex binding sites, reducing agglutination and scattering of light. Decreased light scattering is measured as decreased absorbance at 531 nm. The Hb A1c concentration is then quantified using a calibration curve of absorbance vs. Hb A1c concentration.
Approximately 30 µl of blood was collected via a saphenous vein in conscious mouse. Ten microliters of blood was used to measure Hb A1c. The remaining 20 µl of the blood was sent to Case Western Reserve University via an overnight service to determine total GlyHb (see below). Preliminary studies showed that there was no difference in Hb A1c levels determined in freshly collected blood and that which had been stored for 1 day (data not shown).
Determination of total GlyHb. Total GlyHb in mouse blood was determined using boronate affinity HPLC (Bio-Rad Variant Hemoglobin Testing Systems; Bio-Rad Laboratories, Hercules, CA). Sample hemolysate is passed over the boronate column, and glycated hemoglobin is preferentially bound due to the formation of a stable complex between the coplanar cis-diol group of glycated hemoglobin and the immobilized 3-aminophenylboronic acid in the affinity cartridge. The nonglycated hemoglobin is eluted from the column with subsequent displacement of the glycated hemoglobins using a separate buffer. The separated hemoglobins pass through the flow cell of the filter photometer, where changes in the absorbance are measured at 415 nm. A secondary filter at 690 nm corrects for matrix effects caused by mixing buffers of different ionic strength.
Statistical analysis. All data are expressed as means ± SE. One-way ANOVA followed by a Bonferroni post hoc test was used to compare the difference among three groups, and two-tailed t-test was used for comparison of data between two groups. The level of statistical significance was assigned at P < 0.05 by convention.
| RESULTS |
|---|
|
|
|---|
|
|
|
Blood glucose level following 6 h vs. overnight fasting. To define the optimal fasting time for determining blood glucose in mice, we measured saphenous venous glucose following a 6-h fast in diabetic and control C57BL/6J, DBA/2J, and KK/HlJ mice. One week later, the blood glucose was measured again in the same mice following an overnight fast. The fasting blood glucose was then compared with the daily averaged blood glucose determined with the use of an implanted interstitial glucose sensor in strain- and age-matched mice. Overnight fasting resulted in significantly lower blood glucose in all groups of mice except diabetic C57BL/6J mice (overnight fasting vs. daily averaged blood glucose in control and diabetic C57BL/6J: 109.5 ± 3.2 vs. 158.3 ± 2.5 and 445.8 ± 60.5 vs. 626.8 ± 16.5 mg/dl, respectively; in control and diabetic KK/HlJ mice: 91.5 ± 2.5 vs. 171.2 ± 14.0 and 243.2 ± 16.3 vs. 463.1 ± 30.7 mg/dl, respectively; in control and diabetic DBA/2J mice: 73.5 ± 2.9 vs. 131.7 ± 6.1 and 191.9 ± 57.1 vs. 498.4 ± 60.0 mg/dl, respectively). In contrast, a 6-h fast yielded blood glucose values that were no different from the daily averaged MiniMed determined glucose values.
Six-hour fasting slightly decreased body weight compared with the same mice without a fast (<7%). Overnight fasting resulted in a more marked decrease in body weight (8.0 ± 0.8, 11.0 ± 1.0, and 11.5 ± 1.9% less than 6-h-fasted body weight in control KK/HlJ, DBA/2J, and C57BL/6J mice, respectively, and 6.2 ± 0.7, 5.1 ± 2.1, and 8.7 ± 1.1% in diabetic KK/HlJ, DBA/2J, and C57BL/6J mice, respectively; P < 0.05 in all groups compared with body weight in 6-h-fasted mice). These data indicate that a 6-h fast imposes less metabolic stress on mice than an overnight fast.
Correlation between fasting blood glucose and Hb A1c. The relationship between Hb A1c and 6-h or overnight-fasted blood glucose was also analyzed in C57BL/6J, KK/HlJ, and DBA/2J mice. Six-hour-fasted blood glucose correlated more closely with Hb A1c than overnight-fasted blood glucose, although overnight-fasted blood glucose also correlated with Hb A1c (Fig. 3).
|
The predictive value of total GlyHb for diabetic nephropathy in inbred mice. We have demonstrated previously that diabetic KK/HlJ and DBA/2J mice develop severe nephropathy, whereas C57BL/6J mice appear to resist diabetic nephropathy (25). In the present study, we examined whether the total GlyHb was different in these three strains when correlated with 6-h fasting blood glucose (total GlyHb/fasting blood glucose). The present studies revealed that KK/HlJ and DBA/2J mice, which are susceptible to diabetic nephropathy, exhibit significantly higher GlyHb for any given fasting blood glucose than C57BL/6J mice (Fig. 4).
|
| DISCUSSION |
|---|
|
|
|---|
Therefore, we established a method to continuously measure blood glucose level over 24 h in mice using the CGMS. This system determines glucose level in interstitial fluid. A correlation between interstitial fluid and blood glucose levels has been demonstrated in humans and several other species (19, 21, 28). The present studies further demonstrate that this correlation also exists in inbred mice.
Glucose excursions were observed in both control and diabetic mice, but the extent of glucose excursions was significantly greater in diabetic mice than their controls. The glucose excursion appears to be more pronounced during the night, consistent with the nocturnal nature of mice. Glucose excursions were also seen in some mice during the daytime following saphenous vein bleeding for blood glucose determination. Thus, interruption of daytime sleep by blood sampling may lead mice to consume food, contributing to daytime glucose excursions.
Daily averaged glucose levels are strain dependent. Of the three strains of mice studied, KK/HlJ mice exhibited the highest level of daily blood glucose, whereas the DBA/2J mice had the lowest averaged daily blood glucose. This observation is consistent with previous studies indicating that both KK/HlJ and C57BL/6J mice develop glucose intolerance (8, 33) and that glucose intolerance in KK/HlJ mice is more severe than in C57BL/6J mice (33).
Using daily averaged blood glucose as a reference value, we compared the effect of a 6-h vs. overnight fast on mouse blood glucose. The results indicate that 6-h-fasted blood glucose was closer to the level of daily averaged blood glucose than blood glucose following an overnight fast. In addition, body weight was greater in mice following a 6-h fast than following an overnight fast, consistent with the notion that a 6-h fast imposes less stress than an overnight fast. More importantly, blood glucose following a 6-h fast correlates with Hb A1c better than blood glucose following an overnight fast. This may be explained by the fact that mice are nocturnal feeders, so that initiation of a fast in the evening could effectively result in a 24-h fast, causing inordinately low blood glucose.
In humans, Hb A1c represents the major form of GlyHb and correlates with the averaged blood glucose levels over the preceding 3 mo and the development of diabetic complications (1, 7). The DCA 2000 system is designed to determine Hb A1c on the basis of an immunochemical technique that has been validated against human Hb A1c (2, 13) but has been widely used in mice (18, 36).
To validate Hb A1c values determined using the DCA 2000 analyzer as accurately reflecting GlyHb in mice, we compared these values with a boronate affinity HPLC method that measures total GlyHb on the basis of the presence of coplanar vicinal hydroxyl and/or carbonyl groups of hexoses (23, 24). Comparable values for Hb A1c and total GlyHb in C57BL/6J mice indicate that the Hb A1c determined using DCA 2000 analyzer represents a valid determination of GlyHb in this strain. Considering the small volume of blood required and the convenience and simplicity of operation, this method has considerable utility.
Interestingly, the Hb A1c values were consistently lower than total GlyHb in DBA/2J mice. A difference in Hb A1c determined using DCA 2000 has been observed previously (34). This may be explained by the variation in Hb β-chain alleles in inbred mice (9, 30). For example, DBA/2J appears to be homozygous for the Hbbd β-chain allele, whereas C57Bl/6J is homozygous for the Hbbs allele (30). The allele variation may result in changes in antigenicity and/or glycosylation of hemoglobin. Nevertheless, the close correlations between Hb A1c and total glycosylated Hb, as well as 6-h-fasted blood glucose, indicate that the DCA 2000 is a reliable approach for determination of Hb glycosylation and blood glucose levels in the strains studied. However, the correlations in other strains need to be validated prior to using DCA 2000 approach.
Although the boronate affinity HPLC method has been used as the gold-standard method for GlyHb in humans (23, 24), direct evidence indicating that this is also true in mice is lacking. However, agreement of strain susceptibility to diabetic nephropathy (14, 25) with the ratio of total GlyHb to fasting blood glucose among the strains of mice studied is consistent with boronate HPLC-determined total GlyHb providing a meaningful measurement of GlyHb in mice. The ratio of GlyHb to blood glucose has been suggested to predict diabetic complications in humans (15, 22, 32).
Both blood glucose level and glycosylated Hb are important and widely used parameters in diabetic research. For a short-term study or in settings involved in altered life span of erythrocytes or hemoglobinopathy (20), daily glucose profile and/or fasted blood glucose are more valuable. For long-term studies, especially pertaining to diabetic complications, glycosylated Hb is advantageous in that it is not subject to momentary changes due to stress or some other acute factor. Thus establishing the relationship of glycosylated Hb to fasting glucose will facilitate studies requiring assessment of glucose control.
In summary, we adapted a method to continuously monitor blood glucose in humans to use in conscious mice. The daily averaged blood glucose level determined using the glucose sensor data correlates closely with Hb A1c. Compared with an overnight fast, 6-h fasting blood glucose levels correlate more closely with daily averaged blood glucose levels and Hb A1c. The present studies also demonstrated that Hb A1c determined using the DCA 2000 analyzer correlates with total glycosylated Hb that was determined using a boronate HPLC approach in the three strains of mice studied. Nevertheless, this relationship is strain dependent, and Hb A1c values in DBA/2J mice are relatively lower than total glycosylated hemoglobin compared with C57BL/6J and KK/HlJ mice. Differences in other strains may also exist and should be explored on a strain-by-strain basis. The results of these studies show that Hb A1c measured using a low-cost, hand-held, automated analyzer (DCA 2000) provides an accurate means of assessing glycemic control in the mouse. Use of Hb A1c measurements should permit a more reliable determination of the contribution of blood glucose control to diabetic complications in mouse models.
| GRANTS |
|---|
|
|
|---|
| ACKNOWLEDGMENTS |
|---|
| FOOTNOTES |
|---|
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
| REFERENCES |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
O. P. McGuinness, J. E. Ayala, M. R. Laughlin, and D. H. Wasserman NIH experiment in centralized mouse phenotyping: the Vanderbilt experience and recommendations for evaluating glucose homeostasis in the mouse Am J Physiol Endocrinol Metab, October 1, 2009; 297(4): E849 - E855. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||