1Larry L. Hillblom Islet Research Center, University of California Los Angeles, David Geffen School of Medicine, Los Angeles, California; and 2Endocrine Division, Mayo Medical and Graduate Schools of Medicine, Mayo Clinic, Rochester, Minnesota
Submitted 4 April 2008 ; accepted in final form 23 June 2008
| ABSTRACT |
|---|
|
|
|---|
5 min and an amplitude of up to 600 pmol/l, which was remarkably similar to that in the dogs and in humans. Deconvolution analysis of portal vein insulin concentrations revealed that the majority of insulin (
70%) in the rat is secreted in distinct insulin pulses occurring at
5-min intervals. This model therefore permits direct accurate measurments of pulsatile insulin secretion in a relatively inexpensive animal. With increased introduction of genetically modified rat models will be an important tool in elucidating the underlying mechanisms of impaired pulsatile insulin secretion in diabetes. deconvolution; pulse mass
4 min (23, 30). Therefore, to evaluate pulsatile insulin secretion, it is preferable to sample directly from the portal vein. This has been accomplished in humans under exceptional circumstances (30), but in general animal models are required to investigate pulsatile insulin secretion. Because of blood volume considerations, these studies (21, 24, 25) were for the most part initially carried out in large animals such as the dog. Since anesthesia profoundly suppresses pulsatile insulin secretion (35), we developed a surgical approach that permitted chronic portal vein catheters to allow direct portal vein sampling in the conscious dog (34). By suppressing endogenous insulin secretion and infusing known insulin pulses upstream of the sampling catheter, we then evaluated the most favorable approach to quantify pulsatile insulin secretion from portal vein insulin concentration time series (23). We thereby validated a multiparameter deconvolution program that recovered the known insulin infusion rates and accurately resolved pusaltile from basal nonpulsatile insulin secretion from portal vein insulin concentrations time series (23). We further established the optimal sampling intensity and minimum duration required to reliably quantify insulin secretion from the portal vein (22). Subsequent studies (21, 24, 25) in the canine model provided insights into the regulation of pulsatile insulin secretion.
However, there is an increasing need to bring physiological methods to evaluate rodent genetic models of disturbed glucose metabolism. Recently, it has become feasible to consider similar studies in the rat given the much smaller blood samples required to measure insulin with ELISA methods. Given this development, we sought to extend the approach previously developed and validated in the dog to permit measurement of pulsatile insulin secretion in the conscious free living rat. Since the approach was initially validated in the dog, we simultaneously undertook studies in dogs to permit a direct comparison of the measured insulin secretion profile in the dog and rat.
| RESEARCH DESIGN AND METHODS |
|---|
|
|
|---|
In addition, seven mixed-bred mongrel dogs
1- to 3-yr-old and weighing 20–24 kg were used in the present study. Dogs were housed in individual kennels and fed standard canine chow. Additionally, all dogs were conditioned for at least 3 wk to adapt to a laboratory sling and laboratory personnel. After the conditioning period, complete blood counts were obtained for all dogs to ensure that subjects were within physiological limits. All animal use procedures incorporated in the reported studies were conducted in accordance with an animal use protocol approved by the Institutional Animal Care and Use Committee at the Mayo Clinic. Fasting portal insulin concentration data from these dogs were used in previous study (15).
Surgical implantation of catheters.
Rats were anesthetized by isoflourane (2.5%) inhalation (Isoflourane Vapor 19.1, Summit Anesthesia, Portland, OR). Under aseptic conditions, an approximate 3-cm midline laparotomy was performed to expose the portal and mesenteric veins. with the use of blunt forceps, the portal vein was separated from the underlying connective tissue and an area of
1 cm of the vein was clamped by two smooth small clamps (Fine Science, Foster City, CA) for no longer than 3 min. Thereafter, one stitch was made in the superficial wall of the vein using sterile 7–0 cardiovascular silk thread suture (Western Medical, Arcadia, CA). A 26-gauge needle was then used to penetrate the full thickness of the ventral exposed wall of the portal vein caudal to the anchoring suture. The tip of the portal vein sampling catheter (silastic tubing, 0.051-cm ID cannula with 0.03-cm ID tip) was cut at an angle of
45 degrees (beveled) and then advanced through the hole made by the needle into the lumen of the portal vein and then advanced (
1.5 cm) until the catheter tip was placed at the intrahepatic bifurcation of the portal vein. The catheter was then secured to the vessel with the suture, and the clamps were gently removed. In a subset of animals undergoing validation studies (n = 8), an additional mesenteric vein catheter was inserted. The above-described technique was repeated with the exception that the catheter was placed distal from the liver into the inferior mesenteric vein. The catheters were secured to the abdominal wall by suture, and then the peritoneum and an abdominal muscles were closed with 4-0 Vicryl suture (Western Medical) and the skin in layers with 4.0 nonabsorbable nylon suture (Western Medical). The portal vein and mesenteric vein catheters were then channeled subcutaneously to the back of the neck for encasement into an infusion harness. Additionally, an indwelling catheter was inserted into the left carotid artery (polyethylene tubing, PE-50, Clay Adams 0.058 ID). In short, under aseptic conditions an
2.5-cm neck incision was performed, the underlying connective tissue layer was teased out, and the left carotid artery was exposed. The artery was subsequently ligated above the clavicle, and PE-50 tubing was introduced anterogradely and attached to the artery and underlying tissue by silk suture. All catheters were filled with 100 U/ml of heparin/saline, exteriorized to the back of the neck and encased in the infusion harness (Instech). Catheters were flushed daily with 100 U/ml heparin/saline solution except on the day of the experiment when catheters were aspirated and then flushed with saline only to avoid heparin "spill over" into circulation. Immediately postoperatively, and for the next 3, days all animals received preventative antibiotic treatment (sulfamethoxazole, Hi-Tech Pharmaceutical, Amityville, NY; 200 mg in drinking water). Rats were studied 5–7 days after surgical implantation of catheters. The rats maintained their preoperative body weight and had normal food intake and normal hematocrit (42 ± 2%) at the time of subsequent studies.
The surgical implantation of the portal vein and arterial sampling catheters in the dog has been previously described in detail (23). In brief, after an overnight fast, the dogs were anesthetized using thiobarbiturate. Once anesthesia was achieved, it was subsequently maintained with 1.5–2.5% halothane in 3 liters of oxygen and 2 liters of nitric oxide/min. After exposure through a midline incision, the portal vein was dissected free for a distance of 5–6 cm and the portal vein sampling catheter was placed into the portal vein at the bifurcation of the portal vein in the liver. An arterial sampling catheter was also placed into the carotid artery and similarly tunneled into the subcutaneous pocket. All dogs were studied 2 wk after the surgery week and all recovered their preoperative body weight and had a normal hematocrit (40%), hemoglobin (14 g/dl), and white blood cell count before the study.
Volume of distribution and decay kinetics for insulin in the rat portal vein. Deconvolution of portal vein insulin concentration time series to quantify the corresponding insulin secretion rate requires knowledge of the corresponding volume of distribution and decay constants (i.e., monoexponential vs. biexponential half lives). The model comprises insulin delivered by the pancreas into a tributary of the portal vein and measured at a downstream portal vein sampling catheter. This was accomplished by administration of 1.0, 5.0, or 15 mU of insulin (Novolin, NovoNordisk; in 0.3 ml of saline in 0.25% albumin) via the mesenteric vein catheter over 10 s during suppression of endogenous insulin secretion by somatostatin (Bachem, Torrance, CA) at 10 µg·kg–1·min–1 via the jugular vein catheter. After bolus injection of insulin, blood was sampled from both the portal vein and carotid artery at 15-s intervals for 2 min and thereafter every minute for the next 13 min for measurement of insulin concentrations. The blood glucose concentration was measured at 5-min intervals, and a variable glucose infusion was given via the jugular vein catheter to prevent hypoglycemia. The fitted decay of injected insulin was allowed to proceed to toward postinjection baseline.
Insulin secretion.
On the morning of the study, rats were weighed and sampling extensions were placed on the portal vein and carotid artery sampling catheters. The rats were then placed in a cage outfitted with a counter-weighted-swivel mount (Instech) and allowed to rest for at least 60 min (–90 to –30 min). After a 30-min equilibration period (–30 to 0 min), portal vein blood (
80 µl) was sampled every minute for 35 min and arterial samples (
100 µl) were sampled every 10 min. Blood samples were collected in prechilled microcentrifuge tubes containing protease inhibitor cocktail solution (Sigma, St. Louis, MO) and EDTA (0.15 mg/0.1 ml of blood) and immediately centrifuged. Plasma was immediately stored at –80°C or subsequent analysis. To minimize the effects of frequent blood sampling, blood from a donor animal was quantitatively replaced throughout the study period by administering
1 ml blood every 10 min into the carotid artery catheter. This blood replacement protocol has been shown to have a negligible effect on both systemic and portal vein insulin concentrations.
After an overnight fast (16 h), dogs were placed in a laboratory sling. Portal vein and arterial sampling catheters were exteriorized from the subcutaneous pocket after the use of a local anesthetic. Normal saline was infused through the foreleg infusion catheter at 30 ml/h throughout the study (0–150 min). Blood (
1 ml) was then sampled from the portal vein catheter at 1-min intervals for measurement of the plasma insulin concentrations for 60 min. Additionally, blood samples (
1 ml) were also obtained at 10-min intervals from the arterial catheter for corresponding measurements of plasma insulin concentrations. All samples for plasma insulin were taken into ice-cold glass tubes containing EDTA, immediately cold centrifuged, and stored at –20°C until analyzed. Plasma glucose levels were measured in additional 0.5-ml blood samples using the glucose oxidase method (Beckman Instruments, Fullerton, CA) collected at 10-min intervals from the arterial catheter during the entire study (0–150 min).
Analytical procedures.
Insulin concentrations in rat blood were measured in duplicate by an insulin ELISA (ALPCO Diagnostics, Salem, NH). The primary antibody is specific to rat insulin. The sensitivity range of the assay is 25–931 pmol/l, and all samples >931 pmol/l were diluted to achieve binding in the linear part of the standard curve. Intra- and interassay variation was at 3% or less. Insulin concentrations in dog plasma were measured in triplicate by radioimmunoassay (23). The operating range of the assay is 15 to 968 pmol/l, using 50-µl plasma samples. The intraassay and interassay coefficients of variation were 5 and 15%. Human insulin was measured in duplicate with an in-house two-site immunospecific ELISA. There is no cross-reactivity with proinsulin and split 32,33 and des-31,32 proinsulins. The lower detection limit for this assay is 4 pmol/l, and the assay range is 5–2,000 pmol/l. The intraassay and interassay coefficients of variation were
3 and 5%. Glucose concentrations were measured by the glucose oxidase method (Beckman Glucose Analyzer 2).
Calculations. The portal vein plasma insulin concentrations were subjected to the multiparameter deconvolution analysis as previously described in detail (23). Briefly, multiparameter deconvolution technique used in this study assumes that time varying insulin concentrations can be decomposed mathematically into the following: 1) a finite number of discrete insulin secretory bursts occurring at specific times having 2) individual amplitudes and 3) a common half-duration, wherein bursts are superimposed upon 4) a basal time-invariant insulin secretory rate and 5) insulin disappearance in the portal vein is modeled via rapid and slow half-lives of 0.18 and 1.67 min and fractional slow-component amplitude of 0.065 in the rat (as obtained from this study; Fig. 1) and consisting of half-lives of 0.2 and 3 min in dogs (as obtained previously in Ref. 23). Insulin half-lives were estimated by fitting a biexponential or monoexponential function to the observed insulin concentration series (33). The optimal model was selected by the Akaike information coefficient (1).
|
|
|
| RESULTS |
|---|
|
|
|---|
5 ml. In comparison the volume of distribution in the dog portal vein was 6 ml/kg body wt or on average
140 ml.
Insulin concentrations.
Systemic plasma glucose (96 ± 4 vs. 102 ± 2 mg/dl; P > 0.05; Fig. 2) and insulin concentrations (77 ± 15 vs. 70 ± 9 pmol/l, P > 0.05; Fig. 2) were comparable in both rats and dogs and remained relatively constant during the sampling protocol. Visual examination of portal vein insulin concentration profiles in the fasting state (representative examples shown in Fig. 2) revealed distinct insulin oscillations in both species with a periodicity of
5 min and an average peak amplitude of 310 ± 30 pmol/l.
|
| DISCUSSION |
|---|
|
|
|---|
4–5 min); and 2) as a consequence of this mode of insulin secretion the liver is exposed to insulin oscillations of
400–600 pmol/l in the fasting state.
It is now well established that in health insulin secretion is predominatly derived from discrete insulin secretory bursts that occur at
4-min intervals as a consequence of synchronous discharge of docked insulin secretory vesicles by pancreatic β-cells (17, 18). Since isolated perifused islets secrete insulin in 4-minute pulses (26), the pacemaker dictating the insulin pulse interval is presumably embodied in each islet, with metabolic pacemakers and electrical pacemakers postulated (3). The mechanisms that synchronize the coordinate secretion of pulses by dispersed islets within the pancreas are believed to involve the intrinsic neural network within the pancreas (31). When pulsatile insulin secretion is quantified by a validated approach using insulin measured by ELISA, the pulse interval is not altered in type 2 diabetes, but the magnitude of insulin secretory bursts is deficient (11). Since the latter constitutes the majority of insulin secretion, it is not surprising that insulin secretion is therefore deficient in type 2 diabetes mellitus (20, 29, 32) and is restored to normal if the insulin secretory burst mass is restored (11).
Given these observations, there is interest in understanding the basis of the deficit in insulin pulse mass in type 2 diabetes mellitus. A selective deficit in insulin pulse mass has been reproduced by creating a comparable loss of β-cell mass in a porcine model of type 2 diabetes mellitus (9, 13) and a canine model of impaired fasting glucose (15), implying a potentially important role of β-cell mass. Novel molecular genetic insights into the pathophysiology of type 2 diabetes mellitus are increasingly dependent on genetic manipulation of rodents. However, to date there has been no validated method developed to quantify pulsatile insulin secretion in rodents by direct sampling from the portal vein. Given that we have previously validated a direct portal vein catheterization approach and deconvolution method for measurement of pulsatile insulin secretion in vivo in dogs (23), we elected to extend this approach to the rat once the ELISA methods for measurement of rat insulin concentrations became available. This recent development permits measurement of insulin in a sufficiently small sample size that the multiple sampling required to quantify pulsatile insulin secretion was feasible in rodents.
Evaluation of insulin secretion by use of insulin concentrations measured in the systemic circulation, while technically feasible in humans and animal models, presents a number of significant limitations. It has been shown that hepatic insulin clearance is directly related to the amplitude of insulin pulses in the portal vein (16) and
80% of insulin is cleared in the first pass through the liver (16). Therefore, systemic insulin concentrations may underestimate changes in insulin secretion and pulsatile insulin secretion in particular. Furthermore, hepatic insulin clearance is altered with a decrease in β-cell mass in diabetes (4, 27) and obesity (6) and with aging (2).
The deconvolution approach used here assumes that insulin clearance is constant at the sampling site. To the extent that the insulin clearance varies from minute to minute at the sampling site, the deconvolved insulin secretory rate may be in error. We previously reported that first pass hepatic insulin extraction of endogenous insulin secretion increases in phase with each secretory burst (16) and is proportionate to the magnitude of the insulin burst mass (9, 15, 16). The resulting error in the deconvolved insulin secretion rate may therefore be substantial when quantifying endogenous pulsatile insulin secretion in the systemic sampling site. We originally validated this deconvolution approach for measurement of pulsatile insulin secretion by use of portal vein sampling (23). We compared the deconvolution approach (from portal vein insulin sampling) to direct measurement of the increment in insulin concentration in the portal vein across the pancreas multiplied by portal vein plasma flow (23) over a threefold range of insulin secretion. Reassuringly with portal vein blood sampling the two approaches provided comparable results (23), implying that variance in first pass hepatic insulin extraction (and therefore insulin clearance) at the portal vein sampling site has a negligible effect on the dynamics of insulin concentration compared with the rate of insulin secretion. This is likely reflected in the biexponential decay of insulin decay in the portal vein with a dominant first half life determined predominantly by the portal vein blood flow. These observations further emphasize the importance of developing techniques of measuring pulsatile insulin secretion by direct prehepatic sampling of insulin concentrations from the portal vein.
Perhaps the most striking finding is that the portal vein insulin concentration profile (Fig. 5) in the rat is remarkably similar to that in the dogs (23) and indeed humans (30). These data imply that an insulin concentration oscillatory profile of
400–600 pmol/l is optimal for hepatic insulin signaling in all three species and suggests that the high amplitude portal vein insulin oscillations do have physiological importance. Prior studies (5, 10, 14, 19, 28, 36) have revealed an apparent enhanced action of pulsatile vs. nonpulsatile insulin delivery for suppression of hepatic glucose release, but these studies used much smaller insulin oscillations than those present in the portal vein delivered into the systemic circulation. One negative study (8) reproduced the portal vein pulse amplitude observed in vivo in the dog but at a frequency less than half of that in vivo and to quantify hepatic glucose uptake rather than suppression of hepatic glucose release .
|
4 min. Moreover the resulting insulin concentration profile in the portal vein in all three species consists of distinct insulin oscillations with an amplitude of
400–600 pmol/l and periodicity of 4 min. It remains to be resolved to what extent this high conserved insulin concentration wave front delivered to hepatocytes via hepatic sinusoids is important in insulin signaling. To this end, future studies in rodent models of diabetes with perturbations in insulin secretion will now be possible in which pulsatile insulin secretion is directly measured followed by examination of liver tissue to evaluate hepatic insulin signaling. | GRANTS |
|---|
|
|
|---|
| ACKNOWLEDGMENTS |
|---|
| FOOTNOTES |
|---|
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
| REFERENCES |
|---|
|
|
|---|
50% pancreatectomy. Diabetes: 2347–2356, 2006.This article has been cited by other articles:
![]() |
A. V. Matveyenko, S. Dry, H. I. Cox, A. Moshtaghian, T. Gurlo, R. Galasso, A. E. Butler, and P. C. Butler Beneficial Endocrine but Adverse Exocrine Effects of Sitagliptin in the Human Islet Amyloid Polypeptide Transgenic Rat Model of Type 2 Diabetes: Interactions With Metformin Diabetes, July 1, 2009; 58(7): 1604 - 1615. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. V. Matveyenko, T. Gurlo, M. Daval, A. E. Butler, and P. C. Butler Successful Versus Failed Adaptation to High-Fat Diet-Induced Insulin Resistance: The Role of IAPP-Induced {beta}-Cell Endoplasmic Reticulum Stress Diabetes, April 1, 2009; 58(4): 906 - 916. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. V. Matveyenko, J. D. Veldhuis, and P. C. Butler Adaptations in pulsatile insulin secretion, hepatic insulin clearance, and {beta}-cell mass to age-related insulin resistance in rats Am J Physiol Endocrinol Metab, October 1, 2008; 295(4): E832 - E841. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |