AJP - Endo AJP: Cell Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Endocrinol Metab 277: E561-E571, 1999;
0193-1849/99 $5.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rebrin, K.
Right arrow Articles by Mastrototaro, J. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rebrin, K.
Right arrow Articles by Mastrototaro, J. J.
Vol. 277, Issue 3, E561-E571, September 1999

EPILOGUE
Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring

Kerstin Rebrin1, Garry M. Steil2, William P. van Antwerp1, and John J. Mastrototaro1

1 MiniMed Incorporated, Sylmar, California 91342; and the 2 Massachusetts General Hospital, Boston, Massachusetts 02114

The present study investigated the relationship between blood and subcutaneous interstitial fluid (ISF) glucose by employing an amperometric glucose sensor specifically developed for 3-day continuous glucose monitoring. The apparent sensor sensitivity and ISF glucose equilibration delay were estimated on separate days during hyperglycemic clamps in four dogs in which insulin was either suppressed with somatostatin, allowed to change, or increased with an exogenous infusion. A 2-h sensor "settling-in" period was allowed before the clamps. During insulin deficiency, the sensor sensitivity and ISF glucose delay were 0.23 ± 0.03 nA per mg/dl and 4.4 ± 0.8 min. Sensitivity was not affected by increases in endogenous (0.30 ± 0.04 vs. 0.28 ± 0.04 nA per mg/dl) or exogenous insulin (0.18 ± 0.01 vs. 0.16 ± 0.01 nA per mg/dl) nor was the delay (3.3 ± 1.2 vs. 5.7 ± 1.1 and 9.2 ± 2.6 vs. 12.3 ± 1.7 min; P > 0.05 for all). Sensor glucose accurately predicted plasma glucose without correcting for delays <10 min (r > 0.9 for all), whereas for longer delays a digital corrective filter was used (r = 0.91 with filter). We conclude that the relationship between blood and ISF glucose is not affected by insulin and that delays in ISF glucose equilibration can be corrected with digital filters.

continuous glucose sensor; subcutaneous tissue; interstitial fluid


This article has been cited by other articles:


Home page
Am. J. Physiol. Endocrinol. Metab.Home page
B. G. Han, C.-M. Hao, E. E. Tchekneva, Y.-Y. Wang, C. A. Lee, B. Ebrahim, R. C. Harris, T. S. Kern, D. H. Wasserman, M. D. Breyer, et al.
Markers of glycemic control in the mouse: comparisons of 6-h- and overnight-fasted blood glucoses to Hb A1c
Am J Physiol Endocrinol Metab, October 1, 2008; 295(4): E981 - E986.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Regul. Integr. Comp. Physiol.Home page
H. Ogata, K. Tokuyama, S. Nagasaka, A. Ando, I. Kusaka, N. Sato, A. Goto, S. Ishibashi, K. Kiyono, Z. R. Struzik, et al.
Long-range negative correlation of glucose dynamics in humans and its breakdown in diabetes mellitus
Am J Physiol Regulatory Integrative Comp Physiol, December 1, 2006; 291(6): R1638 - R1643.
[Abstract] [Full Text] [PDF]


Home page
Journal of the American Animal Hospital AssociationHome page
A. E. DeClue, L. A. Cohn, M. E. Kerl, and C. E. Wiedmeyer
Use of Continuous Blood Glucose Monitoring for Animals With Diabetes Mellitus
J. Am. Anim. Hosp. Assoc., May 1, 2004; 40(3): 171 - 173.
[Full Text] [PDF]


Home page
Diabetes CareHome page
E. Kulcu, J. A. Tamada, G. Reach, R. O. Potts, and M. J. Lesho
Physiological Differences Between Interstitial Glucose and Blood Glucose Measured in Human Subjects
Diabetes Care, August 1, 2003; 26(8): 2405 - 2409.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Endocrinol. Metab.Home page
W. Regittnig, M. Ellmerer, G. Fauler, G. Sendlhofer, Z. Trajanoski, H.-J. Leis, L. Schaupp, P. Wach, and T. R. Pieber
Assessment of transcapillary glucose exchange in human skeletal muscle and adipose tissue
Am J Physiol Endocrinol Metab, August 1, 2003; 285(2): E241 - E251.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
A. Chico, P. Vidal-Rios, M. Subira, and A. Novials
The Continuous Glucose Monitoring System Is Useful for Detecting Unrecognized Hypoglycemias in Patients With Type 1 and Type 2 Diabetes but Is Not Better Than Frequent Capillary Glucose Measurements for Improving Metabolic Control
Diabetes Care, April 1, 2003; 26(4): 1153 - 1157.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
B. Guerci, M. Floriot, P. Bohme, D. Durain, M. Benichou, S. Jellimann, and P. Drouin
Clinical Performance of CGMS in Type 1 Diabetic Patients Treated by Continuous Subcutaneous Insulin Infusion Using Insulin Analogs
Diabetes Care, March 1, 2003; 26(3): 582 - 589.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
K. McGowan, W. Thomas, and A. Moran
Spurious Reporting of Nocturnal Hypoglycemia by CGMS in Patients With Tightly Controlled Type 1 Diabetes
Diabetes Care, September 1, 2002; 25(9): 1499 - 1503.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
A. Maran, C. Crepaldi, A. Tiengo, G. Grassi, E. Vitali, G. Pagano, S. Bistoni, G. Calabrese, F. Santeusanio, F. Leonetti, et al.
Continuous Subcutaneous Glucose Monitoring in Diabetic Patients: A multicenter analysis
Diabetes Care, February 1, 2002; 25(2): 347 - 352.
[Abstract] [Full Text] [PDF]


Home page
Clin. DiabetesHome page
J. Unger
Case Study: A 62-Year-Old Man With ""Brittle"" Type 1 Diabetes
Clin. Diabetes, January 1, 2002; 20(1): 37 - 39.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online