AJP - Endo Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Endocrinol Metab 271: E941-E951, 1996;
0193-1849/96 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pietrobelli, A.
Right arrow Articles by Heymsfield, S. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pietrobelli, A.
Right arrow Articles by Heymsfield, S. B.

AJP - Endocrinology and Metabolism, Vol 271, Issue 6 E941-E951, Copyright © 1996 by American Physiological Society


ARTICLES

Dual-energy X-ray absorptiometry body composition model: review of physical concepts

A. Pietrobelli, C. Formica, Z. Wang and S. B. Heymsfield
Obesity Research Center, St. Luke's-Roosevelt Hospital, Columbia University College of Physicians and Surgeons, New York, New York 10025, USA.

Although dual-energy X-ray absorptiometry (DXA) is widely used in clinical research as a means of quantifying body composition, there remains at present little published information that reviews the method's underlying physical basis. Because a clear understanding of DXA physical concepts is integral to appropriate use and interpretation, we present here a three-section review that includes both relevant in vitro and in vivo experimental demonstrations. In the first section we describe the main physical principles on which DXA is based. The section that follows presents a step-by-step analysis of the DXA two-component soft tissue model. In the final section we demonstrate how knowledge of physical concepts can lead to resolution of important methodological concerns, such as the influence of hydration changes on DXA fat estimates. A thorough understanding of DXA physical concepts provides a basis for appropriate interpretation of measurement results and stimulates many new and important research questions.


This article has been cited by other articles:


Home page
Am. J. Physiol. Endocrinol. Metab.Home page
L. Perreault, B. C. Bergman, M. C. Playdon, C. Dalla Man, C. Cobelli, and R. H. Eckel
Impaired fasting glucose with or without impaired glucose tolerance: progressive or parallel states of prediabetes?
Am J Physiol Endocrinol Metab, August 1, 2008; 295(2): E428 - E435.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Endocrinol. Metab.Home page
Z. Wang, S. Heshka, J. Wang, D. Gallagher, P. Deurenberg, Z. Chen, and S. B. Heymsfield
Metabolically active portion of fat-free mass: a cellular body composition level modeling analysis
Am J Physiol Endocrinol Metab, January 1, 2007; 292(1): E49 - E53.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
T. J. Horton, G. K. Grunwald, J. Lavely, and W. T. Donahoo
Glucose kinetics differ between women and men, during and after exercise
J Appl Physiol, June 1, 2006; 100(6): 1883 - 1894.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Endocrinol. Metab.Home page
M.-P. St-Onge, Z. Wang, M. Horlick, J. Wang, and S. B. Heymsfield
Dual-energy X-ray absorptiometry lean soft tissue hydration: independent contributions of intra- and extracellular water
Am J Physiol Endocrinol Metab, November 1, 2004; 287(5): E842 - E847.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Endocrinol. Metab.Home page
A. M. Silva, W. Shen, Z. Wang, J. F. Aloia, M. E. Nelson, S. B. Heymsfield, L. B. Sardinha, and S. Heshka
Three-compartment model: critical evaluation based on neutron activation analysis
Am J Physiol Endocrinol Metab, November 1, 2004; 287(5): E962 - E969.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
J. Kim, S. Heshka, D. Gallagher, D. P. Kotler, L. Mayer, J. Albu, W. Shen, P. U. Freda, and S. B. Heymsfield
Intermuscular adipose tissue-free skeletal muscle mass: estimation by dual-energy X-ray absorptiometry in adults
J Appl Physiol, August 1, 2004; 97(2): 655 - 660.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
T. M. Dean, L. Perreault, R. S. Mazzeo, and T. J. Horton
No effect of menstrual cycle phase on lactate threshold
J Appl Physiol, December 1, 2003; 95(6): 2537 - 2543.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
P. J. Gately, D. Radley, C. B. Cooke, S. Carroll, B. Oldroyd, J. G. Truscott, W. A. Coward, and A. Wright
Comparison of body composition methods in overweight and obese children
J Appl Physiol, November 1, 2003; 95(5): 2039 - 2046.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Endocrinol. Metab.Home page
R. Brommage
Validation and calibration of DEXA body composition in mice
Am J Physiol Endocrinol Metab, September 1, 2003; 285(3): E454 - E459.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Regul. Integr. Comp. Physiol.Home page
M. Rosenbaum, K. Vandenborne, R. Goldsmith, J.-A. Simoneau, S. Heymsfield, D. R. Joanisse, J. Hirsch, E. Murphy, D. Matthews, K. R. Segal, et al.
Effects of experimental weight perturbation on skeletal muscle work efficiency in human subjects
Am J Physiol Regulatory Integrative Comp Physiol, July 1, 2003; 285(1): R183 - R192.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
G. E. van der Ploeg, R. T. Withers, and J. Laforgia
Percent body fat via DEXA: comparison with a four-compartment model
J Appl Physiol, February 1, 2003; 94(2): 499 - 506.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Endocrinol. Metab.Home page
T. J. Horton, S. R. Commerford, M. J. Pagliassotti, and D. H. Bessesen
Postprandial leg uptake of triglyceride is greater in women than in men
Am J Physiol Endocrinol Metab, December 1, 2002; 283(6): E1192 - E1202.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Clin. Nutr.Home page
J. Kim, Z. Wang, S. B Heymsfield, R. N Baumgartner, and D. Gallagher
Total-body skeletal muscle mass: estimation by a new dual-energy X-ray absorptiometry method
Am. J. Clinical Nutrition, August 1, 2002; 76(2): 378 - 383.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Clin. Nutr.Home page
W. W Wong, A. C Hergenroeder, J. E Stuff, N. F Butte, E O'B. Smith, and K. J Ellis
Evaluating body fat in girls and female adolescents: advantages and disadvantages of dual-energy X-ray absorptiometry
Am. J. Clinical Nutrition, August 1, 2002; 76(2): 384 - 389.
[Abstract] [Full Text] [PDF]


Home page
J. Gerontol. A Biol. Sci. Med. Sci.Home page
M. Zamboni, E. Zoico, P. Tosoni, A. Zivelonghi, A. Bortolani, S. Maggi, V. Di Francesco, and O. Bosello
Relation Between Vitamin D, Physical Performance, and Disability in Elderly Persons
J. Gerontol. A Biol. Sci. Med. Sci., January 1, 2002; 57(1): M7 - 11.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Endocrinol. Metab.Home page
S. B. Heymsfield, D. Gallagher, D. P. Kotler, Z. Wang, D. B. Allison, and S. Heshka
Body-size dependence of resting energy expenditure can be attributed to nonenergetic homogeneity of fat-free mass
Am J Physiol Endocrinol Metab, January 1, 2002; 282(1): E132 - E138.
[Abstract] [Full Text] [PDF]


Home page
J. Nutr.Home page
K. Sjogren, N. Hellberg, M. Bohlooly-Y, L. Savendahl, M. S. Johansson, T. Berglindh, I. Bosaeus, and C. Ohlsson
Body Fat Content Can Be Predicted In Vivo in Mice Using a Modified Dual-Energy X-Ray Absorptiometry Technique
J. Nutr., November 1, 2001; 131(11): 2963 - 2966.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Endocrinol. Metab.Home page
Z. Wang, F. X. Pi-Sunyer, D. P. Kotler, J. Wang, R. N. Pierson Jr., and S. B. Heymsfield
Magnitude and variation of ratio of total body potassium to fat-free mass: a cellular level modeling study
Am J Physiol Endocrinol Metab, July 1, 2001; 281(1): E1 - E7.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Clin. Nutr.Home page
H. Santana, E. Zoico, E. Turcato, P. Tosoni, L. Bissoli, M. Olivieri, O. Bosello, and M. Zamboni
Relation between body composition, fat distribution, and lung function in elderly men
Am. J. Clinical Nutrition, April 1, 2001; 73(4): 827 - 831.
[Abstract] [Full Text] [PDF]


Home page
J. Nutr.Home page
K. M. Flegal, R. P. Troiano, and R. Ballard-Barbash
Aim for a Healthy Weight: What Is the Target?
J. Nutr., February 1, 2001; 131(2): 440S - 450.
[Abstract] [Full Text]


Home page
J. Appl. Physiol.Home page
C. G. Testolin, R. Gore, T. Rivkin, M. Horlick, J. Arbo, Z. Wang, G. Chiumello, and S. B. Heymsfield
Dual-energy X-ray absorptiometry: analysis of pediatric fat estimate errors due to tissue hydration effects
J Appl Physiol, December 1, 2000; 89(6): 2365 - 2372.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
R. Shih, Z. Wang, M. Heo, W. Wang, and S. B. Heymsfield
Lower limb skeletal muscle mass: development of dual-energy X-ray absorptiometry prediction model
J Appl Physiol, October 1, 2000; 89(4): 1380 - 1386.
[Abstract] [Full Text] [PDF]


Home page
J. Nutr.Home page
G. W. Welch and M. R. Sowers
The Interrelationship between Body Topology and Body Composition Varies with Age among Women
J. Nutr., September 1, 2000; 130(9): 2371 - 2377.
[Abstract] [Full Text]


Home page
Am. J. Clin. Nutr.Home page
L. B Houtkooper, S. B Going, J. Sproul, R. M Blew, and T. G Lohman
Comparison of methods for assessing body-composition changes over 1 y in postmenopausal women
Am. J. Clinical Nutrition, August 1, 2000; 72(2): 401 - 406.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Clin. Nutr.Home page
G. Barera, S. Mora, P. Brambilla, A. Ricotti, L. Menni, S. Beccio, and C. Bianchi
Body composition in children with celiac disease and the effects of a gluten-free diet: a prospective case-control study
Am. J. Clinical Nutrition, July 1, 2000; 72(1): 71 - 75.
[Abstract] [Full Text] [PDF]


Home page
Physiol. Rev.Home page
K. J. Ellis
Human Body Composition: In Vivo Methods
Physiol Rev, April 1, 2000; 80(2): 649 - 680.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Clin. Nutr.Home page
L. B Sardinha, S. B Going, P. J Teixeira, and T. G Lohman
Receiver operating characteristic analysis of body mass index, triceps skinfold thickness, and arm girth for obesity screening in children and adolescents
Am. J. Clinical Nutrition, December 1, 1999; 70(6): 1090 - 1095.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
W. C. Fornetti, J. M. Pivarnik, J. M. Foley, and J. J. Fiechtner
Reliability and validity of body composition measures in female athletes
J Appl Physiol, September 1, 1999; 87(3): 1114 - 1122.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
W. Wang, Z. Wang, M. S. Faith, D. Kotler, R. Shih, and S. B. Heymsfield
Regional skeletal muscle measurement: evaluation of new dual-energy X-ray absorptiometry model
J Appl Physiol, September 1, 1999; 87(3): 1163 - 1171.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Endocrinol. Metab.Home page
Z. Wang, P. Deurenberg, W. Wang, A. Pietrobelli, R. N. Baumgartner, and S. B. Heymsfield
Hydration of fat-free body mass: new physiological modeling approach
Am J Physiol Endocrinol Metab, June 1, 1999; 276(6): E995 - E1003.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Clin. Nutr.Home page
Z. Wang, P. Deurenberg, W. Wang, A. Pietrobelli, R. N Baumgartner, and S. B Heymsfield
Hydration of fat-free body mass: review and critique of a classic body-composition constant
Am. J. Clinical Nutrition, May 1, 1999; 69(5): 833 - 841.
[Abstract] [Full Text] [PDF]


Home page
J. Nutr.Home page
G. B. Forbes
Body Composition: Overview
J. Nutr., January 1, 1999; 129(1): 270S - 270S.
[Abstract] [Full Text] [PDF]


Home page
J. Nutr.Home page
E. Bertin, J.-C. Ruiz, J. Mourot, P. Peiniau, and B. Portha
Evaluation of Dual-Energy X-Ray Absorptiometry for Body-Composition Assessment in Rats
J. Nutr., September 1, 1998; 128(9): 1550 - 1554.
[Abstract] [Full Text]


Home page
Am. J. Physiol. Endocrinol. Metab.Home page
A. Pietrobelli, Z. Wang, C. Formica, and S. B. Heymsfield
Dual-energy X-ray absorptiometry: fat estimation errors due to variation in soft tissue hydration
Am J Physiol Endocrinol Metab, May 1, 1998; 274(5): E808 - E816.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online