AJP - Endo Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Endocrinol Metab 264: E561-E566, 1993;
0193-1849/93 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow A corrigendum has been published
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Katz, H.
Right arrow Articles by Rizza, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Katz, H.
Right arrow Articles by Rizza, R.

AJP - Endocrinology and Metabolism, Vol 264, Issue 4 E561-E566, Copyright © 1993 by American Physiological Society


ARTICLES

Hepatic and extrahepatic insulin action in humans: measurement in the absence of non-steady-state error

H. Katz, P. Butler, M. Homan, A. Zerman, A. Caumo, C. Cobelli and R. Rizza
Department of Medicine, Mayo Clinic and Foundation, Rochester, Minnesota 55905.

The isotope dilution technique has been extensively used to assess insulin action in humans. To determine if nonsteady state (NSS) has led to erroneous estimates of hepatic and extrahepatic insulin sensitivity, we measured glucose turnover in healthy subjects during infusion of insulin at rates of 0.25, 0.6, and 2.0 mU.kg-1.min-1. Turnover was calculated using Steele's traditional NSS equations [fixed-effective volume (pV) method] as well as with methods [radioactive infused glucose (hot-GINF) or variable pV] designed to minimize NSS error. In contrast to the fixed-pV method, both the hot-GINF and variable-pV methods indicated that several hours were required for suppression of hepatic glucose release at all insulin concentrations and that small increases in plasma insulin (approximately 100 pmol/l) had comparable effects on glucose disappearance and hepatic glucose release. Nevertheless, despite these differences, when turnover during the final hour of the insulin infusions was plotted vs. the prevailing insulin concentration, all three methods yielded similar insulin dose-response curves for suppression of hepatic glucose release. Thus despite previous errors in measurement of glucose turnover, the widely accepted belief that the human liver is exquisitely sensitive to small changes in insulin is correct.


This article has been cited by other articles:


Home page
Am. J. Physiol. Endocrinol. Metab.Home page
R. L. Prigeon, S. Quddusi, B. Paty, and D. A. D'Alessio
Suppression of glucose production by GLP-1 independent of islet hormones: a novel extrapancreatic effect
Am J Physiol Endocrinol Metab, October 1, 2003; 285(4): E701 - E707.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Endocrinol. Metab.Home page
R. E. Van Pelt, W. S. Gozansky, R. S. Schwartz, and W. M. Kohrt
Intravenous estrogens increase insulin clearance and action in postmenopausal women
Am J Physiol Endocrinol Metab, August 1, 2003; 285(2): E311 - E317.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Endocrinol. Metab.Home page
T. Utriainen, S. Lovisatti, S. Makimattila, A. Bertoldo, S. Weintraub, R. DeFronzo, C. Cobelli, and H. Yki-Jarvinen
Direct measurement of the lumped constant for 2-deoxy-[1-14C]glucose in vivo in human skeletal muscle
Am J Physiol Endocrinol Metab, July 1, 2000; 279(1): E228 - E233.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Endocrinol. Metab.Home page
A. Caumo, P. Vicini, J. J. Zachwieja, A. Avogaro, K. Yarasheski, D. M. Bier, and C. Cobelli
Undermodeling affects minimal model indexes: insights from a two-compartment model
Am J Physiol Endocrinol Metab, June 1, 1999; 276(6): E1171 - E1193.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Endocrinol. Metab.Home page
E. Cersosimo, P. Garlick, and J. Ferretti
Insulin regulation of renal glucose metabolism in humans
Am J Physiol Endocrinol Metab, January 1, 1999; 276(1): E78 - E84.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Endocrinol. Metab.Home page
J. O. Nygren, A. Thorell, M. Soop, S. Efendic, K. Brismar, F. Karpe, K. S. Nair, and O. Ljungqvist
Perioperative insulin and glucose infusion maintains normal insulin sensitivity after surgery
Am J Physiol Endocrinol Metab, July 1, 1998; 275(1): E140 - E148.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Endocrinol. Metab.Home page
D. K. Sindelar, C. A. Chu, D. W. Neal, and A. D. Cherrington
Interaction of equal increments in arterial and portal vein insulin on hepatic glucose production in the dog
Am J Physiol Endocrinol Metab, November 1, 1997; 273(5): E972 - E980.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online