AJP - Endo Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Endocrinol Metab 263: E28-E35, 1992;
0193-1849/92 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Davis, S. N.
Right arrow Articles by Alberti, K. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Davis, S. N.
Right arrow Articles by Alberti, K. G.

AJP - Endocrinology and Metabolism, Vol 263, Issue 1 E28-E35, Copyright © 1992 by American Physiological Society


ARTICLES

Dose-response characteristics of human proinsulin and insulin in non-insulin-dependent diabetic humans

S. N. Davis, L. Monti, P. M. Piatti, M. Brown, C. Hetherington, H. Orskov, W. Sobey, C. N. Hales and K. G. Alberti
Department of Medicine, Medical School, University of Newcastle upon Tyne, United Kingdom.

We compared the actions of human proinsulin and insulin on glucose turnover and on intermediary carbohydrate and lipid metabolism in non-insulin-dependent diabetes mellitus (NIDDM). Six diet-controlled weight-matched (25.4 +/- 1.0 kg/m2) NIDDM subjects underwent six separate isoglycemic clamps. Glucose turnover was measured using a primed continuous infusion of [6',6'-2H2]glucose. Each subject received three low-dose intravenous infusions of both insulin and proinsulin. Blood glucose was maintained at 6.7 +/- 0.3 mM during proinsulin and insulin infusion. Insulin (I) infusions gave steady-state levels of 0.12 +/- 0.001 (I1), 0.18 +/- 0.01 (I2), and 0.33 +/- 0.01 nM (I3). Steady-state proinsulin (P) levels were 2.5 +/- 0.1 (P1), 4.3 +/- 0.2 (P2), and 8.8 +/- 0.9 nM (P3). Hepatic glucose production was suppressed equally by proinsulin and insulin at all doses. The metabolic clearance rate of glucose was significantly increased during the insulin infusion compared with proinsulin. The use of [6',6'-2H2]glucose resulted in a mean underestimation of the glucose infusion rate of 10.0 +/- 4.0 and 6.0 +/- 2.5% during the two highest insulin and proinsulin doses, respectively. Proinsulin had a significantly weaker effect than insulin, at the lowest infusion dose, in percent suppression of plasma nonesterified fatty acids, blood glycerol, and beta-hydroxybutyrate levels (all P less than 0.05). Blood lactate levels were lower during the P1 (628 +/- 43 microM) and P2 (657 +/- 93 microM) infusions compared with I1 (776 +/- 60 microM) and I2 (878 +/- 44 microM; P less than 0.05, P less than 0.02), respectively.(ABSTRACT TRUNCATED AT 250 WORDS)