AJP - Endo Cosmo Bio: Excellent Endocrine ELISAs
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Endocrinol Metab 254: E113-E119, 1988;
0193-1849/88 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Urban, R. J.
Right arrow Articles by Veldhuis, J. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Urban, R. J.
Right arrow Articles by Veldhuis, J. D.

AJP - Endocrinology and Metabolism, Vol 254, Issue 1 E113-E119, Copyright © 1988 by American Physiological Society


ARTICLES

Comparative assessments of objective peak-detection algorithms. II. Studies in men

R. J. Urban, D. L. Kaiser, E. van Cauter, M. L. Johnson and J. D. Veldhuis
Department of Internal Medicine, University of Virginia School of Medicine, Charlottesville 22908.

The performances of eight currently available computerized pulse-detection algorithms were compared on signal-free noise and physiological luteinizing hormone (LH) time series. Signal-free noise was made to vary from 4 to 36% for Gaussian and empirical distributions. Physiological LH data were obtained by immunoassay of blood samples withdrawn every 5 min for 24 h in 8 healthy men, so that the data sets could be emended to simulate varying sampling intensities. Whenever possible, programs were tested at a presumptive 1% false-positive rate. In relation to signal-free noise, the Santen and Bardin program and its modification manifested elevated false-positive rates when the intraseries coefficients of variation increased. The Regional Dual-Threshold program yielded a 1% false-positive rate except on simulated series with high variance. The Cluster and Detect programs both approximated a 1% false-positive rate and the Ultra program approximated a 2.3% false-positive rate throughout the entire range of variance tested. In regard to physiological LH data, all algorithms disclosed a significant impact of sampling intensity on estimates of LH pulse frequency. Sampling-intensity dependent estimates of LH peak frequency by three of the eight programs (Ultra, Cluster, and Detect) were statistically indistinguishable from each other but distinct from the five other programs tested. Furthermore, when judged in relation to their ability to identify individual peaks, the three congruent programs were minimally distinguishable (McNemar's test). Rather, these programs identified the same particular peaks (as defined by concordance of peak maxima) at least 72% of the time.


This article has been cited by other articles:


Home page
DiabetesHome page
L. L. Kjems, M. A. Ravier, J.-C. Jonas, and J.-C. Henquin
Do Oscillations of Insulin Secretion Occur in the Absence of Cytoplasmic Ca2+ Oscillations in {beta}-Cells?
Diabetes, February 1, 2002; 51(90001): S177 - 182.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online